射頻探針
Model 120 (75 to 110 GHz )
Model 120 (75 to 110 GHz / WR-10 waveguide input) 波導探針
  • 規格參數
  • 資料下載


High Performance Microwave Probes

Model 120

Features

  • Durable 75 GHz to 110 GHz
  • Insertion loss 1.75 db max (75 to 110 GHz)
  • Return loss 15 db max (75 to 110 GHz)
  • Individually spring loaded contacts
  • Measurement repeatability -50 db
  • Bias T option available
  • Patented coaxial design




undefined

FIGURE 1

The MODEL 120 PICOPROBE? sets new standards in microwave probing performance. Benefiting from coaxial techniques, which have inherent low loss and low dispersion characteristics, the Model 120 Picoprobe?, achieves an insertion loss of less than 1.75 db (typical) and a return loss of greater than 15 db (max.) over its frequency range.

With its individually spring loaded, Beryllium-Copper tips, the Model 120 Picoprobe? provides reliable contacts, even when probing non-planar structures. This reliable low resistance contact is one of the keys to providing highly repeatable measurements (-50 db) at W band frequencies. The Model 120 Picoprobe also provides direct viewing of the probe tips for accurate positioning.

Any pitch (tip spacing) from 50 microns to 450 may be specified. The probe can be configured with Ground-Signal-Ground (G,S,G), Ground-Signal (G,S), or Signal-Ground (S,G) tip footprints. We recommend smaller pitches with a G,S,G footprint for best performance.




120btl
left: Typical uncalibrated performance of a Model 120-GSG-150-BT while touching a 50 Ohm load on our CS-5 Calibration Substrate.
120btr
left: Typical insertion loss of a Model 120-GSG-150-BT.
120bloss

left: The Picoprobe? Model 120's Bias T provides a direct low resistance DC path for supplying up to 1.5 A to a device under test. The Bias T has special circuits which add loss at frequencies below the cut-off frequency (59.05 GHz) of WR-10 waveguide. This data was taken by launching a 40 MHz to 67 GHz signal from the tips of a calibrated Model 67A into the tips of a Model 120-GSG-150-BT. Without this low frequency loss, most active devices will oscillate.
120smith

left: Forward reflection of a Model 120 into an open ended 50 ps coplanar line after an LRM/TRM calibration was performed using our

CS-5 Calibration Substrate. The smooth inwardly spiraling line shows the increasing loss of the 50 ps coplanar line with frequency, coupled with a smoothly changing phase. The CS-5 Calibration Substrate will also perform excellent LRL/TRL and SOLT W-band calibrations. More data is available on request.

FIGURE 2

Micropositioners are available to hold Wiltron V band modules so that the module and the probe are micropositioned as a unit. In this way, total ease of positioning can be achieved with minimum insertion loss.
The probes also have a 3 hole mounting adaptor which will fit standard microwave probe stations. In this case, a longer section of waveguide may be desired to add positioning flexibility.
undefined
FIGURE 3
120lit6 (1)
Model 120-BT Waveguide Dimensions


Model 120-BT-M Waveguide Dimensions

FIGURE 4






推薦產品
主站蜘蛛池模板: 看全色黄大色黄女片爽在线看 | 欧美一级特黄aaaaaaa色戒 | 精品综合久久久久久888蜜芽 | 99久久免费精品 | 亚洲色成人网站www永久小说 | 亚洲久久成人 | 欧美激情在线一区二区 | 去看片在线 | 老司机AⅤ在线精品导航 | 国产偷久久一级精品60部 | 中文字幕永久网 | 这里只有精品在线播放 | 亚洲国产成人高清精品 | 欧美一级片在线观看 | 国产高清中文手机在线观看 | 国产精品视频久久久久久 | 日韩av最新网址 | 91成人国产 | 麻豆人人妻人人妻人人片AV | 夜鲁鲁鲁夜夜综合视频欧美 | 国产a毛片 | 日韩欧美精品在线播放 | JAPANESE少妇高潮喷水 | 99视频| 性高潮久久久久 | 一本一道av无码中文字幕麻豆 | 亚洲国产AV一区二区三区丶 | 国产在线观看二区 | 亚洲综合一区二区三区四区 | 日本网站视频 | 91自拍.com | 蘑菇视频黄色 | 香蕉高清永久在线视频 | 成人影院视频 | 四虎网站最新地址 | 亚洲欧美日韩综合久久久久 | 66成人网 | 亚洲色成人中文字幕网站 | 国产精品一区2区3区 | 亚洲色欲在线播放一区二区三区 | 国产精品日韩AV在线播放 |