射頻探針
Model 120 (75 to 110 GHz )
Model 120 (75 to 110 GHz / WR-10 waveguide input) 波導探針
  • 規格參數
  • 資料下載


High Performance Microwave Probes

Model 120

Features

  • Durable 75 GHz to 110 GHz
  • Insertion loss 1.75 db max (75 to 110 GHz)
  • Return loss 15 db max (75 to 110 GHz)
  • Individually spring loaded contacts
  • Measurement repeatability -50 db
  • Bias T option available
  • Patented coaxial design




undefined

FIGURE 1

The MODEL 120 PICOPROBE? sets new standards in microwave probing performance. Benefiting from coaxial techniques, which have inherent low loss and low dispersion characteristics, the Model 120 Picoprobe?, achieves an insertion loss of less than 1.75 db (typical) and a return loss of greater than 15 db (max.) over its frequency range.

With its individually spring loaded, Beryllium-Copper tips, the Model 120 Picoprobe? provides reliable contacts, even when probing non-planar structures. This reliable low resistance contact is one of the keys to providing highly repeatable measurements (-50 db) at W band frequencies. The Model 120 Picoprobe also provides direct viewing of the probe tips for accurate positioning.

Any pitch (tip spacing) from 50 microns to 450 may be specified. The probe can be configured with Ground-Signal-Ground (G,S,G), Ground-Signal (G,S), or Signal-Ground (S,G) tip footprints. We recommend smaller pitches with a G,S,G footprint for best performance.




120btl
left: Typical uncalibrated performance of a Model 120-GSG-150-BT while touching a 50 Ohm load on our CS-5 Calibration Substrate.
120btr
left: Typical insertion loss of a Model 120-GSG-150-BT.
120bloss

left: The Picoprobe? Model 120's Bias T provides a direct low resistance DC path for supplying up to 1.5 A to a device under test. The Bias T has special circuits which add loss at frequencies below the cut-off frequency (59.05 GHz) of WR-10 waveguide. This data was taken by launching a 40 MHz to 67 GHz signal from the tips of a calibrated Model 67A into the tips of a Model 120-GSG-150-BT. Without this low frequency loss, most active devices will oscillate.
120smith

left: Forward reflection of a Model 120 into an open ended 50 ps coplanar line after an LRM/TRM calibration was performed using our

CS-5 Calibration Substrate. The smooth inwardly spiraling line shows the increasing loss of the 50 ps coplanar line with frequency, coupled with a smoothly changing phase. The CS-5 Calibration Substrate will also perform excellent LRL/TRL and SOLT W-band calibrations. More data is available on request.

FIGURE 2

Micropositioners are available to hold Wiltron V band modules so that the module and the probe are micropositioned as a unit. In this way, total ease of positioning can be achieved with minimum insertion loss.
The probes also have a 3 hole mounting adaptor which will fit standard microwave probe stations. In this case, a longer section of waveguide may be desired to add positioning flexibility.
undefined
FIGURE 3
120lit6 (1)
Model 120-BT Waveguide Dimensions


Model 120-BT-M Waveguide Dimensions

FIGURE 4






推薦產品
主站蜘蛛池模板: 内谢少妇xxxxx8老少交 | 英语老师解开裙子坐我腿中间 | 成人福利视频 | 国产精品制服 | 极品无码国模国产在线观看 | japanese日本护士高潮 | 深夜免费福利视频 | 2018av天堂在线视频精品观看 | 大地资源在线视频资源 | 精品国产一区在线 | a级毛片在线观看 | 亚洲精品无码AV在线观看 | 日本三级日本三级韩国三级视 | 国产最顶级的黄色片在线免费观看 | 久久久国产精品福利片 | 日本不卡在线一区二区三区视频 | aaa一区 | 国产精品色婷婷在线观看 | 青苹果乐园免费高清资源 | 一级毛片免费完整视频 | 足疗店女技师按摩毛片 | 日本在线看 | a免费在线| 欧美性猛交99久久久久99 | 少妇裸体淫交视频免观看 | 久久亚洲美女 | 欧美无人区码卡二卡3卡4破解 | 一级毛片中文字幕 | 樱花草在线观看播放免费视频 | 欧美日韩高清不卡 | 成人黄网站片免费视频 | 亚洲国产的精品太乱码一区二区 | 日产精品久久久久久久性色 | 国产性色一区二区 | 欧美精品一区二区性色 | 2020年最新国产精品正在播放 | 91久久精品日日躁夜夜躁国产 | 免费视频在线播放啪 | 91正在播放 | 激情不卡一区二区三区视频在线 | 美女视频一级片 |