欧美搔妇久久久久久岬奈奈美_性欧美videofree护士pic_国产超碰91_九九亚洲精品爱在线_免播放器在线视频_国产亚洲精品久久19p

射頻探針
Model 120 (75 to 110 GHz )
Model 120 (75 to 110 GHz / WR-10 waveguide input) 波導探針
  • 規格參數
  • 資料下載


High Performance Microwave Probes

Model 120

Features

  • Durable 75 GHz to 110 GHz
  • Insertion loss 1.75 db max (75 to 110 GHz)
  • Return loss 15 db max (75 to 110 GHz)
  • Individually spring loaded contacts
  • Measurement repeatability -50 db
  • Bias T option available
  • Patented coaxial design




undefined

FIGURE 1

The MODEL 120 PICOPROBE? sets new standards in microwave probing performance. Benefiting from coaxial techniques, which have inherent low loss and low dispersion characteristics, the Model 120 Picoprobe?, achieves an insertion loss of less than 1.75 db (typical) and a return loss of greater than 15 db (max.) over its frequency range.

With its individually spring loaded, Beryllium-Copper tips, the Model 120 Picoprobe? provides reliable contacts, even when probing non-planar structures. This reliable low resistance contact is one of the keys to providing highly repeatable measurements (-50 db) at W band frequencies. The Model 120 Picoprobe also provides direct viewing of the probe tips for accurate positioning.

Any pitch (tip spacing) from 50 microns to 450 may be specified. The probe can be configured with Ground-Signal-Ground (G,S,G), Ground-Signal (G,S), or Signal-Ground (S,G) tip footprints. We recommend smaller pitches with a G,S,G footprint for best performance.




120btl
left: Typical uncalibrated performance of a Model 120-GSG-150-BT while touching a 50 Ohm load on our CS-5 Calibration Substrate.
120btr
left: Typical insertion loss of a Model 120-GSG-150-BT.
120bloss

left: The Picoprobe? Model 120's Bias T provides a direct low resistance DC path for supplying up to 1.5 A to a device under test. The Bias T has special circuits which add loss at frequencies below the cut-off frequency (59.05 GHz) of WR-10 waveguide. This data was taken by launching a 40 MHz to 67 GHz signal from the tips of a calibrated Model 67A into the tips of a Model 120-GSG-150-BT. Without this low frequency loss, most active devices will oscillate.
120smith

left: Forward reflection of a Model 120 into an open ended 50 ps coplanar line after an LRM/TRM calibration was performed using our

CS-5 Calibration Substrate. The smooth inwardly spiraling line shows the increasing loss of the 50 ps coplanar line with frequency, coupled with a smoothly changing phase. The CS-5 Calibration Substrate will also perform excellent LRL/TRL and SOLT W-band calibrations. More data is available on request.

FIGURE 2

Micropositioners are available to hold Wiltron V band modules so that the module and the probe are micropositioned as a unit. In this way, total ease of positioning can be achieved with minimum insertion loss.
The probes also have a 3 hole mounting adaptor which will fit standard microwave probe stations. In this case, a longer section of waveguide may be desired to add positioning flexibility.
undefined
FIGURE 3
120lit6 (1)
Model 120-BT Waveguide Dimensions


Model 120-BT-M Waveguide Dimensions

FIGURE 4






推薦產品
主站蜘蛛池模板: 嫩草影院永久久久精品 | 亚洲欧美在线视频观看 | 久色一区 | 殴美在线 | 一本之道加勒比在线观看 | 欧美人与动zozo | 国产成人精品123区免费视频 | 日本不卡视频在线播放 | gogogo高清在线播放免费观看免费 | 免费在线观看色视频 | 午夜国产精品影院在线观看 | 四虎影免看黄 | 久草视频在线免费播放 | 日产精品久久久久久久性色91 | 超碰综合 | 无码av一区在线观看免费 | 亚洲国产福利成人一区 | 亚洲欧美色αv在线影视 | gogogo高清免费观看中国 | 激情美女一区 | 男女性杂交内射女BBWXZ | 乳色av| 国产精品久久久久9999无码 | 国产视频一区二区三区在线观看 | 91探花在线观看 | 日本黄色小视频 | 国产毛片毛片毛片毛片毛片毛片 | 成人做爰高潮片免费看视频 | 免费午夜小视频 | 欧美aaaaaa午夜精品 | 国产精品高 | 亚洲欧洲毛片 | 99re只有精品 | 欧美激情视频一区二区三区 | 欧美综合图区 | 欧美精品一本久久男人的天堂 | 亚洲日本久久 | 婷婷色婷婷开心五月四房播播 | 天天看天天射 | 四虎影院免费观看 | 国产又粗又黄又爽的A片精华 |